NC2XRY-cc XLPE Insulated, PVC sheathed, Armoured Copper Control Cables Voltage rating 0.6/1kV.
Normes
Internationales  IEC 60502-1
Description

Construction

  • Conductor of round stranded copper wires/shaped stranded copper wires 
  • Insulation of cross-linked polyethylene (XLPE)
  • PVC Inner sheath
  • Steel Wire Armouring
  • PVC Outer Sheath

 

ABREVATION:

N - Kabelmetal standard type

C - Copper conductor

2X - Cross linked PE (XLPE) insulation

Y - Polyvinyl chloride (PVC) inner sheath

R - Round steel wire armour

Y - Polyvinyl chloride (PVC) outer sheath

cc - Control Cables

 

Application

As control cables for installation underground, outdoors and in ducts.


 TOP
Caractéristiques
Caractéristiques de construction
Nature de l'âme Plain copper  
Forme de l'âme Round solid  
Isolation PRC  
Gaine extérieure PVC  
Gaine interne PVC  
Caractéristiques électriques
Tension de service nominale Uo/U 0,6 / 1 kV  
Max. system voltage, 1-phase grounded 0,7kV  
Max. system voltage: 1 phase both phases grounded (Um) 1,2kV  
Caractéristiques d'utilisation
U.V resistance if required  
Non propagateur de la flamme IEC 60332-3 Cat. A  
Facteur de courbure en cours de pose 10(xD)  
Minimum installation temperature 90°C  
Température maximale sur l'âme 90°C  
Température maximale sur l'âme en court circuit 250°C  

 TOP
Recherche Paramétrique
Section du conducteur  mm²
Diamètre extérieur approximatif  mm
Masse approximative  kg/km
Longueur  m
Intensité admissible enterré  A
Intensité admissible à l'air libre  A
Max. system voltage 3 phases (Um)  kV
Appliquer
Annuler
Votre sélection   22/22
Sélectionner tous les produits Code article Désignation du produit Section du conducteur (mm²) Diamètre extérieur approximatif (mm) Masse approximative (kg/km)
430513-85 NC2XRY-cc 5 x 1.5 1,5 15,2 404
430514-85 NC2XRY-cc 5 x 2.5 2,5 16,9 561
430713-85 NC2XRY-cc 7 x 1.5 1,5 16,7 542
430714-85 NC2XRY-cc 7 x 2.5 2,5 17,9 647
431013-85 NC2XRY-cc 10 x 1.5 1,5 19,5 687
431014-85 NC2XRY-cc 10 x 2.5 2,5 21,4 883
431213-85 NC2XRY-cc 12 x 1.5 1,5 20,1 742
431214-85 NC2XRY-cc 12 x 2.5 2,5 22,0 959
431613-85 NC2XRY-cc 16 x 1.5 1,5 21,8 917
431614-85 NC2XRY-cc 16 x 2.5 2,5 23,6 1134
431913-85 NC2XRY-cc 19 x 1.5 1,5 22,6 990
431914-85 NC2XRY-cc 19 x 2.5 2,5 23,4 1090
432413-85 NC2XRY-cc 24 x 1.5 1,5 24,2 1033
432414-85 NC2XRY-cc 24 x 2.5 2,5 26,6 1320
432713-85 NC2XRY-cc 27 x 1.5 1,5 24,8 1095
432714-85 NC2XRY-cc 27 x 2.5 2,5 27,2 1437
433313-85 NC2XRY-cc 33 x 1.5 1,5 26,2 1250
433314-85 NC2XRY-cc 33 x 2.5 2,5 29,0 1667
433713-85 NC2XRY-cc 37 x 1.5 1,5 27,0 1330
433714-85 NC2XRY-cc 37 x 2.5 2,5 30,0 894
434013-85 NC2XRY-cc 40 x 1.5 1,5 27,8 1423
434014-85 NC2XRY-cc 40 x 2.5 2,5 31,2 962
Ajouter aux favoris

 TOP
AVAILABLE 1.5mmsq AND 2.5mmsq CONTROL CABLES
XLPE Insulated, PVC Sheathed, Armoured Copper Control Cables, 0.6/1kV

Nominal 
Cross Sectional
Area

Number and 
Diameter of Wire

Nominal 
Overall 
Diameter

Maximum Permissible 
Current Rating 
Amp

Standard 
Delivery 
Length

Weight 
per Standard 
Delivery L

Delivery 
on Wooden 
Drum

mm²

No x mm

mm

In Ground @ 20°C

In Air @ 30°C

m

kg

 

5 x 1.5

1 x 1.38

15.2

26

19.5

1000

404

R12

7 x 1.5

1 x 1.38

16.7

23

17

1000

542

R12

10 x 1.5

1 x 1.38

19.5

19

14

1000

687

R12

12 x 1.5

1 x 1.38

20.1

17

14

1000

742

R12

16 x 1.5

1 x 1.38

21.8

16

12

1000

917

R14

19 x 1.5

1 x 1.38

22.6

15

12

1000

990

R14

24 x 1.5

1 x 1.38

24.2

13

10

1000

1033

R14

27 x 1.5

1 x 1.38

24.8

13

10

1000

1095

R14

33 x 1.5

1 x 1.38

26.2

12

9

1000

1250

R14

37 x 1.5

1 x 1.38

27

11

9

1000

1330

R16

40 x 1.5

1 x 1.38

27.8

11

9

1000

1423

R16

5 x 2.5

1 x 1.78

16.9

34

27

1000

561

R12

7 x 2.5

1 x 1.78

17.9

29

23

1000

647

R12

10 x 2.5

1 x 1.78

21.4

24

20

1000

883

R14

12 x 2.5

1 x 1.78

22

23

19

1000

959

R14

16 x 2.5

1 x 1.78

23.6

21

17

1000

1134

R14

19 x 2.5

1 x 1.78

23.4

20

16

1000

1090

R14

24 x 2.5

1 x 1.78

26.6

17

14

1000

1320

R16

27 x 2.5

1 x 1.78

27.2

17

14

1000

1437

R16

33 x 2.5

1 x 1.78

29

16

13

1000

1667

R16

37 x 2.5

1 x 1.78

30

16

13

500

894

R14

40 x 2.5

1 x 1.78

31.2

14

13

500

962

R14

Maximum permissible current rating values stated for cables laid in ground are based on load factor of 0.7 and for cables intalled in air, a load factor of 1.0