A propos de Nexans
Produits et Solutions
Service client
Carrières
Infos Presse
For data transmission without electromagnetic smog. Used in festoon systems on cranes and other material handling equipment.
Optical Fibers Fiber types: ...E9/125 µm, ...G50/125 µm and ...G62.5/125 µm Fibers layed in a gel filled high performance thermoplastic loose tubes
Strain Relief High-end synthetic rovings
Outer sheath Heavy duty chlorinated rubber compound 5GM5 acc. DIN VDE 0207 part 21
e.g.: RHEYCORD-OFE MZ 2x12G62.5/125 I NEXANS I year
DIN EN 188000
Fibre types
…E9/125ITU-T G.652.DOS2 acc. IEC 60793-2-50ISO/IEC 24072
…G50/125ITU-T G.651OM2 acc. IEC 60793-2-10ISO/IEC 11801
…G62.5/125ITU-T G.651OM1 acc. IEC 60793-2-10ISO/IEC 11801
Geometrical characteristics
Mode field diameter
9.0 ± 0,5 µm
50 ± 3 µm
62.5 ± 3 µm
Core non-circularity
≤ 5.0 %
Cladding diameter
125 ± 2 µm
Cladding non-circularity
≤ 2 %
Coating diameter
245 ± 10 µm
Numerical aperture
-
0.200 ± 0.015
0.275 ± 0.015
Optical characteristics
Attenuation coefficient:@ 850 nm@ 1310 nm@ 1550 nm
≤ 0.5 dB/km≤ 0.4 dB/km
≤ 3.0 dB/km≤ 1.0 dB/km
≤ 3.5 dB/km≤ 1.5 dB/km
Bandwidth:@ 850 nm@ 1300 nm
≥ 600 MHz*km≥ 1200 MHz*km
≥ 200 MHz*km≥ 500 MHz*km
Chromatic Dispersion:1270 - 1340 nm1285 - 1330 nm1550 nm
< 5.0 ps/nm*km< 3.5 ps/nm*km< 18 ps/nm*km
Index of reflaction (IOR):@ 850 nm@ 1300 nm@ 1310 nm@ 1550 nm
1.4671.467
1.496 1.491
1.4677 1.4682
Mechanical characteristics
Strip force (peak)
1.3 ≤ Fpeak strip ≤ 8.9 N
Proof test
690 N/mm²
Test elongation for 1 s
1.0 %
…E9/125…G50/125…G62.5/125
This table describes the colour coding of the different fiber optics.Rings are added for number of fiber over 12
1
2
3
4
5
6
7
8
9
10
11
12
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
13
14
15
16
17
18
19
20
21
22
23
24
1 ring
2 rings
max. permissible torsional stress
≤ 120 ° / m
Permissible bending radii:- fixed installation- reeling application- festoon application
≥ 50 mm≥ 250 mm≥ 125 mm
tests
alternating/reversed bending test, roller bending test,torsional resistance test, tensile load test
Travel speed (festoon system)
up to 240 m/minhigher speed on request